Samsung Hylex Heat Pump Condensing Unit, 208-230 V, 24.4 A, 125 W, 60 Hz, 1-Phase, 3 Fan Speeds, 34600 Btu/hr Heating, 36000 Btu/hr Cooling, 2684 cfm Heating CFM Rating, 9.3 EER Rating, 18 SEER, 9.5 HSPF, Pipe Connection, 3/8 in Liquid Line, 7/8 in Suction Line, Inverter Drive, 55 dB Heating Sound Level, 53 dB Cooling Sound Level, Steel, Finish: Powder-Coated, -13 to 75 deg F Heating Operating Temperature, 23 to 125 deg F Cooling Operating Temperature, 37 in Overall Length, 39-5/16 in Overall Width, 13 in Overall Height
| Amperage Rating |
: |
24.4 A |
| Connection Type |
: |
Pipe |
| Cooling BTU Rating |
: |
36000 Btu/hr |
| Cooling Operating Temperature |
: |
23 to 125 deg F |
| Cooling Sound Level |
: |
53 dB |
| Drive Type |
: |
Inverter |
| EER Rating |
: |
9.3 |
| Finish |
: |
Powder-Coated |
| Frequency Rating |
: |
60 Hz |
| HSPF Rating |
: |
9.5 |
| Heating BTU Rating |
: |
34600 Btu/hr |
| Heating CFM Rating |
: |
2684 cfm |
| Heating Operating Temperature |
: |
-13 to 75 deg F |
| Heating Sound Level |
: |
55 dB |
| Liquid Line Size |
: |
3/8 in |
| Material |
: |
Steel |
| Number of Fan Speeds |
: |
3 |
| Overall Height |
: |
13 in |
| Overall Length |
: |
37 in |
| Overall Width |
: |
39-5/16 in |
| Phase |
: |
1 ph |
| Power Rating |
: |
125 W |
| SEER Rating |
: |
18 |
| Suction Line Size |
: |
7/8 in |
| Voltage Rating |
: |
208-230 V |
- Inverter driven heat pump condensing unit compatible with air handling units and A-coils with a thermostatic expansion valve (conditions apply, refer to supporting technical documents for details).
- 100% Rated heating capacity at 5degF (-15degC) outside temperature (refer to capacity tables in outdoor unit technical data book for full capacity details).
- Soft-start compressor minimizing current inrush
- Base pan heater equipped as standard
- The condensing unit heat exchanger salt spray test method: ISO-9227 - The heat exchanger showed no unusual rust or corrosion development to 3,000 hours.
- The system (outdoor unit with MXD-U000XN AHU Control Unit) shall provide three (3) fan speed control of the indoor unit increasing performance and dehumidification
- The unit shall be galvanized steel with a baked-on powder coated finish for durability
- Refrigerant pipe connections and service ports are located inside the heat pump cabinet. Refrigerant pipes can enter the cabinet on the front, side, back, or bottom
- Requires MXD-U000XN AHU Control Unit (purchased separately) installed near the indoor unit for operation
- Control wiring shall be 2 X 18 AWG (minimum)
- Compatible with standard 24VAC thermostats
- Requires B reversing valve signal (24VAC energized for heating)
- The system (outdoor unit with AHU Control Unit) shall provide cold air prevention (optional) to delay indoor fan operation until the indoor coil is above a fixed temperature while in heat mode.
- Target low pressure calibration to increase or decrease indoor coil and discharge air temperature in cooling mode
- Target high pressure calibration to increase or decrease indoor section coil and discharge air temperature in heating mode
- Snow accumulation prevention option setting to prevent snow drifting against an idle outdoor unit
- The outdoor unit shall feature optional night quiet modes to reduce outdoor unit sound (3 levels) with automatic activation or manual activation (with MIM-B14 accessory)
- System can be set up as heating/cooling, cooling only, or heating only via outdoor unit option setting
- Maximum Current Control configurable from 50% - 100% in 5% increments via outdoor unit
- The compressor shall be hermetically sealed, inverter-controlled BLDC rotary type
-