Samsung CXH36ADB SAM AC036BXADCH

Samsung CXH36ADB Multi-Position Air Handler Outdoor Unit, 208-230 V, 24.5 A, 36000 Btu/hr Cooling, 1 ph-Phase, Steel

  • Manufacturer: Samsung
  • Brand Name: Samsung
  • Part Number: SAM AC036BXADCH
  • MPN: CXH36ADB
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Sign In for Availability

Samsung Multi-Position Air Handler Outdoor Unit, 208-230 V, 24.5 A, 125 W, 60 Hz, 1-Phase, 3 Fan Speeds, 40000 Btu/hr Heating, 36000 Btu/hr Cooling, 3532 cfm Heating CFM Rating, 1229 cfm Cooling CFM Rating, 9.6 EER Rating, 16.6 SEER, 8.4 HSPF, Pipe Connection, 3/8 in Liquid Line, 5/8 in Suction Line, Inverter Drive, 54 dB Heating Sound Level, 52 dB Cooling Sound Level, Steel, Finish: Powder-Coated, -4 to 75 deg F Heating Operating Temperature, 23 to 122 deg F Cooling Operating Temperature, 37 in Overall Length, 47-11/16 in Overall Width, 13 in Overall Height

Amperage Rating      :      24.5 A
Connection Type      :      Pipe
Cooling BTU Rating      :      36000 Btu/hr
Cooling CFM Rating      :      1229 cfm
Cooling Operating Temperature      :      23 to 122 deg F
Cooling Sound Level      :      52 dB
Drive Type      :      Inverter
EER Rating      :      9.6
Finish      :      Powder-Coated
Frequency Rating      :      60 Hz
HSPF Rating      :      8.4
Heating BTU Rating      :      40000 Btu/hr
Heating CFM Rating      :      3532 cfm
Heating Operating Temperature      :      -4 to 75 deg F
Heating Sound Level      :      54 dB
Liquid Line Size      :      3/8 in
Material      :      Steel
Number of Fan Speeds      :      3
Overall Height      :      13 in
Overall Length      :      37 in
Overall Width      :      47-11/16 in
Phase      :      1 ph
Power Rating      :      125 W
SEER Rating      :      16.6
Suction Line Size      :      5/8 in
Voltage Rating      :      208-230 V
  • The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire
  • High-voltage terminal block temperature sensor to disable unit in the event of power connection overheating
  • Auto-restart after power loss
  • Soft-start compressor minimizing current inrush
  • All heat exchangers shall be mechanically bonded aluminum fin to copper tube
  • The condensing unit heat exchanger salt spray test method: ISO-9227- the heat exchanger showed no unusual rust or corrosion development to 3,000 hours
  • Maximum Current Control configurable from 50% - 100% via outdoor unit, wired controller, or central controller
  • The outdoor unit shall have snow accumulation prevention option setting to prevent snow drifting against an idle outdoor unit
  • Night-time Quiet Mode: reduction of operational sound during evening hours (automatic or manual activation)
  • System can be set up as heating/cooling, cooling only, or heating only via outdoor unit option setting
  • Control wiring shall be 2 X 16 AWG
  • No additional interface modules/adapters are required when connecting to Samsung central control options
  • The unit shall be operated via a wireless or wired remote control with DDC type signal
  • Dual set temperature support when connected to MWR-WG00UN Advanced Wired Controller or central control options
  • Wired or wireless controllers must be purchased separately
  • pdfSpecification Sheet https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_CNH36ZDB_Submittal.pdf