Samsung Multi-Position Air Handler Outdoor Unit, 208-230 V, 9.8 A, 40 W, 60 Hz, 1-Phase, 3 Fan Speeds, 14000 Btu/hr Heating, 12000 Btu/hr Cooling, 1060 cfm Heating CFM Rating, 399 cfm Cooling CFM Rating, 12 EER Rating, 20.7 SEER, 10.8 HSPF, Pipe Connection, 1/4 in Liquid Line, 3/8 in Suction Line, Inverter Drive, 48 dB Heating Sound Level, 47 dB Cooling Sound Level, Steel, Finish: Powder-Coated, -4 to 75 deg F Heating Operating Temperature, 23 to 122 deg F Cooling Operating Temperature, 31-1/8 in Overall Length, 21-9/16 in Overall Width, 11-1/4 in Overall Height
| Amperage Rating |
: |
9.8 A |
| Connection Type |
: |
Pipe |
| Cooling BTU Rating |
: |
12000 Btu/hr |
| Cooling CFM Rating |
: |
399 cfm |
| Cooling Operating Temperature |
: |
23 to 122 deg F |
| Cooling Sound Level |
: |
47 dB |
| Drive Type |
: |
Inverter |
| EER Rating |
: |
12 |
| Finish |
: |
Powder-Coated |
| Frequency Rating |
: |
60 Hz |
| HSPF Rating |
: |
10.8 |
| Heating BTU Rating |
: |
14000 Btu/hr |
| Heating CFM Rating |
: |
1060 cfm |
| Heating Operating Temperature |
: |
-4 to 75 deg F |
| Heating Sound Level |
: |
48 dB |
| Liquid Line Size |
: |
1/4 in |
| Material |
: |
Steel |
| Number of Fan Speeds |
: |
3 |
| Overall Height |
: |
11-1/4 in |
| Overall Length |
: |
31-1/8 in |
| Overall Width |
: |
21-9/16 in |
| Phase |
: |
1 ph |
| Power Rating |
: |
40 W |
| SEER Rating |
: |
20.7 |
| Suction Line Size |
: |
3/8 in |
| Voltage Rating |
: |
208-230 V |
- The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire
- High-voltage terminal block temperature sensor to disable unit in the event of power connection overheating
- Integral condensate pump with maximum 29" lift from bottom of the unit with check valve and float switch that disables indoor should condensate overflow be detected
- Auto-restart after power loss
- Soft-start compressor minimizing current inrush
- All heat exchangers shall be mechanically bonded aluminum fin to copper tube
- The condensing unit heat exchanger salt spray test method: ASTM-B117-18 - the heat exchanger showed no unusual rust or corrosion development to 500 hours
- Base pan heaters equipped as standard
- The outdoor unit shall have snow accumulation prevention option setting to prevent snow drifting against an idle outdoor unit
- Night-time Quiet Mode: reduction of operational sound during (automatic or manual activation)
- Emergency Temperature Output (ETO) function: when indoor unit is in error status or when room temperature exceeds configurable temperature level, the system outputs a signal to an external source, e.g., backup system, building management system, alert device (ex: status light, warning lamp, buzzer)
- System can be set up as heating/cooling, cooling only, or heating only via outdoor unit option setting
- Maximum Current Control configurable from 50% - 100% via outdoor unit, wired controller or central control
- Control wiring shall be 2 X 16 AWG wire
- No additional interface modules/adapters are required when connecting to Samsung central control options
- The unit shall be operated via a wireless or wired remote control with DDC type signal
- Dual set temperature support when connected to MWR-WG00UN Advanced Wired Controller or central control options
- Wired or wireless controllers must be purchased separately
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_CXH12ADB_Specification_Sheet.pdf