The ICM2916 is a form, fit, and functional replacement for the boards shown in the cross-reference section of this guide. The control boards are designed as automated gas ignition controls which monitor the ignition sequence including the inducer, pressure switch, spark ignition, gas valve, flame sense, and circulating blower while maintaining full safety circuit monitoring including the high limit switch, roll out switch and auxiliary limit switch circuits. Onboard diagnostics will indicate when a fault condition exists.
ICM™ Direct Spark Ignition Control Board, 240 V, 1.5 A, Pre Purge Time: 20 s, 1 hr Lockout, Additional Information: 0.75 uA Minimum Flame Signal Threshold, 18 to 30 VAC Control Voltage, 50/60 Hz Line Frequency
| Additional Information | : | 0.75 uA Minimum Flame Signal Threshold, 18 to 30 VAC Control Voltage, 50/60 Hz Line Frequency |
| Amperage Rating | : | 1.5 A |
| Lockout Time | : | 1 hr |
| Pre Purge Time | : | 20 s |
| Voltage Rating | : | 240 V |